Precise and effective dosing of products that are manually difficult to dose.
Operating conditions
Hours of operation per day: 8 Days of operation per week: 5 Ambient temperature: 10 – 40°C
Technical Data
Nominal voltage: 24 V DC (power supply for 220 V enclosed) Power consumption: 30 – 240 W Motor speed: 50 – 250 rpm Footprint: width 350 mm x depth 350 mm Total height: 700 mm (optional 1,000 mm) Height under filling nozzle: 10 – 235 mm Weight: 16.4 kg (without power supply) Dosage with step size • 0.1 g: 0.1 – 49.9 g • 1.0 g: 50.0 – 32,500.0 g Filling accuracy: Maximal 2% deviation Maximum suction lift: n. a. Maximum volume flow: 14.0 l/min Filling temperature: 2 – 95°C
Triggering of the filling process
Foot switch (included) Frame switch (included) Sensor (optional for operation with rotary table)